Efektifitas Pembayangan yang dihasilkan Pohon dan Bangunan di Koridor Jalan Perkotaan Untuk Mencapai Kenyamanan Termal

Authors

  • Jockie Zudhy Fibrianto Politeknik Negeri Pontianak
  • Mochamad Hilmy Politeknik Negeri Pontianak

DOI:

https://doi.org/10.29080/emara.v4i1.177

Keywords:

thermal comfort, road corridors, shading

Abstract

The road corridor in Pontianak City has different shading output depending on the sun orientation. The difference has caused a temperature difference that affects the pedestrian thermal comfort along the corridor. Identification and measurement of shading temperatures that occur due to buildings and trees were carried out for three days in each afternoon with relatively similar weather conditions. The road corridor that becomes the research location was at A. Yani St.-Gajah Mada St.-Tanjung Pura St., which has a North-South orientation and Teuku Umar St.-Diponegoro St.-Sisingamangaraja St., who has an East-West direction. The analysis phase is done by comparing the effectiveness of imagery produced by buildings and trees. After that, the identification and measurement results are compared with Indonesian thermal comfort standards SNI T-14-1993-03 to obtain suitable thermal comfort in the road corridors in Pontianak City.

Downloads

Download data is not yet available.

References

Auliciems, Andris, S., & V., S. (2007). Thermal Comfort. Queensland: Department of Architecture, The University of Queensland Brisbane.

Baharuddin, I., M.Taufik, B., Syarif, O., & M.Yoenus. (2013). Analisis Kenyamanan dan Lingkungan Termal pada Ruang Kuliah dengan Ventilasi Alami (Studi Kasus: Kampus II Fakultas Teknik Unhas Gowa). Semesta Arsitektur Nusantara 2; Arsitektur Nusantara Berkelanjutan. Malang: Jurusan Arsitektur Universitas Brawijaya.

Dotulong, A. L. (2008). Pengaruh Pembayangan Massa Bangunan Terhadap Radiasi Panas Matahari Di Ruang Terbuka Kawasan Tropis Yang Terletak Pada Garis Lintang 7°Ls. Jurnal Arsitektur & Perencanaan ,3(1) , 1-11.

Indraswara, M. S., & Rifan, Y. (2013). Pengaruh Sistem Pembayangan Pada Bentuk Fasade Bangunan Perkantoran yang Hemat Energi (Studi Kasus Bangunan Kolonial di Kota Lama Semarang). Modul, 13(1) , 41-48.

Lippsmeier, G. (1994). Bangunan Tropis. Jakarta: Erlangga.

Lisa, & Nova Purnama, N. (2017). Pengaruh Adaptasi Arsitektur Tropis pada Bangunan Kolonial di Koridor Jalan Blang Mee Samudera Pase. Seminar Heritage IPLBI 2017 (pp. B111-B118). Cirebon: IPLBI.

Nikolopoulou, M., & Lykoudis, S. (2006). Thermal Comfort in Outdoor Urban Spaces: Analysis Across Different European Countries. Building and Environment, 1455-1470.

Satwiko, & Prasasto. (2008). Fisika Bangunan. Yogyakarta: Andi.

Sugini. (2004). Pemaknaan Istilah-Istilah Kualitas Kenyamanan Thermal Ruang Dalam Kaitan dengan Variabel Iklim Ruang. Logika , 3-17.

Downloads

Published

2018-08-27

How to Cite